EasyManua.ls Logo

Siemens SINAMICS S110 - p20223[0...1] CI: NSW 1 inputs; NSW 1 inputs; p20224 BI: NSW 1 switch setting I; NSW 1 sw_setting; r20225 CO: NSW 1 output Y; NSW 1 output Y; p20226 NSW 1 run-time group; NSW 1 RTG

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameter
1-713
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the signal source of input quantities X0 and X1 of instance NSW 1 of the numeric changeover switch.
Index: [0] = Input X0
[1] = Input X1
Description: Sets the signal source of the switch setting I of instance NSW 1 of the numeric changeover switch.
Description: Display parameter for output quantity Y of instance NSW 1 of the numeric changeover switch.
Description: Setting parameter for the run-time group in which the instance NSW 1 of the numeric changeover switch is to be
called.
p20223[0...1] CI: NSW 1 inputs / NSW 1 inputs
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: 7250
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p20224 BI: NSW 1 switch setting I / NSW 1 sw_setting
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 7250
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
r20225 CO: NSW 1 output Y / NSW 1 output Y
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 7250
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - -
p20226 NSW 1 run-time group / NSW 1 RTG
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed: T Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: 7250
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 9999 9999