List of parameters
Parameter
1-421
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets a fixed value for torque.
Dependency: Refer to: p2900, p2901
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note: The value can, for example, be used to interconnect a supplementary torque.
Description: Torque constant for the synchronous motor determined by the motor data identification.
This torque constant can be changed after the identification and accepted in p0316 with p1910/p1960 = -3.
Dependency: Refer to: p0316, r0334, r1937, p1960
Description: Voltage constant for a synchronous motor determined by the motor data identification.
This voltage constant can be changed after the identification and accepted in p0317 with p1910/p1960 = -3.
Units for rotating synchronous motors: Vrms/(1000 rpm), phase-to-phase
Dependency: Refer to: r1938, p1960
Description: Magnetizing current for an induction motor determined by the motor data identification.
This magnetizing current can be changed after the identification and accepted in p0320 with p1910/p1960 = -3.
Dependency: Refer to: p0320, r0331, p1910, r1948, p1960
p2930[0...n] CO: Fixed value M [Nm] / Fixed value M [Nm]
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: DDS, p0180 Func. diagram: 1021
P-Group: Free function blocks Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: p2003 Expert list: 1
Min Max Factory setting
-100000.00 [Nm] 100000.00 [Nm] 0.00 [Nm]
p3016 MotId torque constant identified / kT ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: 28_1 Unit selection: p0100
Not for motor type: ASM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
0.00 [Nm/A] 100.00 [Nm/A] 0.00 [Nm/A]
p3017 MotId voltage constant identified / kE ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
0.0 [Vrms] 10000.0 [Vrms] 0.0 [Vrms]
p3020 MotId magnetizing current identified / I_mag ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
0.000 [Arms] 5000.000 [Arms] 0.000 [Arms]