Parameter
List of parameters
1-428
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the global status word for messages.
The appropriate bit is set if at least one message is present at the drive objects.
Note: The status bits are displayed with delay.
Description: Displays the drive object number of the initiating drive object for this fault as integer number.
Value = 63:
The fault was initiated by the drive object itself.
Dependency: Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136, r3120, r3122
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the fault buffer and the assignment of the indices is shown in r0945.
Description: Sets the signal source for the automatic acknowledgement on the device drive object.
BI: p3116 = 0 signal
Faults present are automatically acknowledged on the device drive object. Local device faults are forwarded to the
first active drive object.
BI: p3116 = 1 signal
Faults present are not automatically acknowledged on the device drive object. Local device faults are not for-
warded.
Dependency: Refer to: p2102, p2103, p2104, p2105, p3981
Note: When selecting a standard telegram, the BICO interconnection for control signal STW1.10 (master control by PLC)
is automatically established.
r3114.9...11 CO/BO: Messages status word global / Msg ZSW global
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
09 Alarm present Yes No 8065
10 Fault present Yes No 8060
11 Safety message present Yes No -
r3115[0...63] Fault drive object initiating / F DO initiating
All objects Can be changed: - Calculated: - Access level: 3
Data type: Integer32 Dynamic index: - Func. diagram: 1750, 8060
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p3116 BI: Acknowledgement automatically suppressed / Ackn suppress
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 8060
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0