Function diagrams
Internal control/status words
2-820
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-62 2530 – Status word, current control
- 2530 -
Function diagram
87654321
fp_2530_98_eng.vsd
DO: SERVO
SINAMICS S110
30.10.08 V04.04.00
Internal control/status words - Status word, current control
r1408
ZSW closed-loop
current control
1
2
1 = Closed-loop current control active
Meaning
Reserved
Reserved
0
Bit No.
Status word closed-loop current control
3
4
Reserved
5
6
7
8
9
Reserved10
11 Reserved
12 Reserved
13 Reserved
14 Reserved
15 Reserved
Refer to [1020.7]
250 s
1 = Limiting Ud active
1 = Limiting Uq active
1 = Pos. limit. Iq active
1 = Neg. limit. Iq active
1 = Iq setpoint limit. active
1 = Id setpoint limit. active
r1408.5 [5040.7][5042.5]
[5714.5]
r1408.6
[5714.4]
r1408.7
[5714.4]r1408.8
[5722.7]r1408.9
r1408.4