List of parameters
Parameter
1-147
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the signal source for terminal DI/DO 10 (X132.3).
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: Prerequisite: The DI/DO must be set as an output (p0728.10 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 11 (X132.4).
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: Prerequisite: The DI/DO must be set as an output (p0728.11 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DO 16.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Terminal DO 16 is used for Safety Extended Functions if these have been enabled using p9601 and are not con-
trolled via PROFIsafe, and provided that a signal source has been set for the F-DO using p10042.
The signal source entered in p0746 is then no longer output at terminal DO 16.
Note: DO: Digital Output
Description: Displays the status of digital outputs.
p0740 BI: CU, signal source for terminal DI/DO 10 / CU S_src DI/DO 10
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 1510, 2031,
2497, 2498
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p0741 BI: CU, signal source for terminal DI/DO 11 / CU S_src DI/DO 11
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 1510, 2031,
2497, 2498
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p0746 BI: CU signal source for terminal DO 16 / CU S_src DO 16
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 1510, 2032
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
r0747 CU, digital outputs status / CU DO status
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 2130, 2131,
2132, 2133
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -