Fig. 2-67 2548 – Status word, faults/alarms 1 and 2
- 2548 -
Function diagram
87654321
fp_2548_98_eng.vsd
DO: All objects
SINAMICS S110
28.10.08 V04.04.00
Internal control/status words - Status word, faults/alarms 1 and 2
Source sampling time
Refer to [1020.7]
3
...
9
r2135
ZSW faults/alarms 2
0
r2139.3
r2139.7
r2135.14
r2135.15
r2135.13
r2135.12
r2139.0
r2139.6
r2135.0
r2135.1
r2135.2
From the thermal monitoring, power module [8014.8]
From the thermal monitoring, power module [8014.8]
From the thermal monitoring, motor [8016.8]
From the thermal monitoring, motor [8016.8]
r2139.8
From the alarm buffer [8065.4]
From the fault buffer [8060.6]
1 = Fault, encoder 1
Status word, faults/alarms 2
1 = Fault, encoder 2
1 = Fault, encoder 3
1 = Alarm transformer overtemperature
1 = Fault motor overtemperature
1 = Fault, thermal overload, power module
1 = Acknowledgement running
Status word, faults/alarms 1
1 = Fault present
Reserved
1 = Internal signal 2 present
1 = Alarm motor overtemperature
1 = Alarm, thermal overload, power module
1 = Internal signal 1 present
1 = Alarm present
1 = Safety signal present
2
1
Bit No.
r2139.5
4
6
7
8
12
13
14
15
0
Bit No.
5
3
r2139.11
Reserved9
Reserved10
1 = Alarm class bit 011
r2139.121 = Alarm class bit 112
Reserved
Reserved
1
2
Reserved13
Reserved14
Reserved15
11
1 = Fault transformer overtemperature10
From the thermal monitoring, transformer [8016.8]
From the thermal monitoring, transformer [8016.8]
r2135.11
r2135.10
Reserved
r2139
ZSW faults/alarms 1