EasyManua.ls Logo

Siemens SINAMICS S110 - p2585 EPOS jog 1 setpoint velocity; Jog 1 v_set; p2586 EPOS jog 2 setpoint velocity; Jog 2 v_set; p2587 EPOS jog 1 traversing distance; Jog 1 distance; p2588 EPOS jog 2 traversing distance; Jog 2 distance

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-382
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the setpoint velocity for jog 1.
Dependency: Refer to: p2587, p2589, p2591
Description: Sets the setpoint velocity for jog 2.
Dependency: Refer to: p2588, p2590, p2591
Description: Sets the traversing distance for incremental jog 1.
Dependency: Refer to: p2585, p2589, p2591
Note: Incremental jog 1 is started with BI: p2591 = 1 signal and BI: p2589 = 0/1 signal.
With BI: p2589 = 0 signal, incremental jog is interrupted.
Description: Sets the traversing distance for incremental jog 2.
Dependency: Refer to: p2586, p2590, p2591
Note: Incremental jog 2 is started with BI: p2591 = 1 signal and BI: p2590 = 0/1 signal.
With BI: p2590 = 0 signal, incremental jogging is interrupted.
p2585 EPOS jog 1 setpoint velocity / Jog 1 v_set
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3610
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-40000000 [1000 LU/min] 40000000 [1000 LU/min] -300 [1000 LU/min]
p2586 EPOS jog 2 setpoint velocity / Jog 2 v_set
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3610
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-40000000 [1000 LU/min] 40000000 [1000 LU/min] 300 [1000 LU/min]
p2587 EPOS jog 1 traversing distance / Jog 1 distance
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 3610
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [LU] 2147482647 [LU] 1000 [LU]
p2588 EPOS jog 2 traversing distance / Jog 2 distance
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 3610
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [LU] 2147482647 [LU] 1000 [LU]