Siemens SINAMICS S110 - r4689[0...2] CO: Squarewave encoder, diagnostics; Sq­wave enc diag; p4690 SMI spare part component number; SMI comp_no; p4691 SMI spare part save;download data; Save;DL SMI data

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameter
1-447
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency: Refer to: p4681, p4682, p4683, p4684
Note: The display can only be reset to zero.
Description: Displays the encoder status according to PROFIdrive for a squarewave encoder.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency: Refer to: A31422
Note: After alarm A3x422 is output, this parameter is set for 100 ms.
Description: Sets the component number for the SMI/DQI for which motor and/or encoder data should be saved, deleted or
downloaded.
Dependency: Refer to: p4691, p4692, p4693
Note: DQI: DRIVE-CLiQ Sensor Integrated
SMI: SINAMICS Sensor Module Integrated
Description: Setting to save/download the data for the Sensor Module Integrated (SMI) specified in p4690.
Procedure:
p4690 = set component number
p4691 = 1, 2, 3, 30 set the required procedure (save/download/delete)
p4691 = 9, 10, 36 automatic on successful completion of the procedure
p4691 = 11... 22, 37, 38 --> error values if the procedure could not be executed
Value: 0: Inactive
1: Save SMI data
2: Download SMI data
3: Download SMI data from memory card
9: SMI data downloaded and POWER ON required for component
10: SMI data backup complete
11: SMI data backup for selected component not found
12: Selected component not available or not connected
13: Insufficient memory space for backup
14: Format of saved data is incompatible
15: Transfer fault during data download
16: Transfer fault during data backup
r4689[0...2] CO: Squarewave encoder, diagnostics / Sq-wave enc diag
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p4690 SMI spare part component number / SMI comp_no
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 399 0
p4691 SMI spare part save/download data / Save/DL SMI data
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: T Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 38 0