Parameter
List of parameters
1-476
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Index: [0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Description: Displays the output signal for the free measurement function.
Index: [0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Dependency: Refer to: p4810
Note: The signals are only output in the "free measurement function" operating mode (p4810 = 6)
Description: Sets the scaling of the output signals for the free measurement function.
Index: [0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Note: The parameter cannot be changed when the measurement function has been started (r4706 = 2, 3).
Description: Displays the status for the file system on the non-volatile memory.
The individual result data and characteristic data are summarized in a corresponding file.
r4834[0...4] CO: Function generator free measurement output signal / FG fr MeasFct outp
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 0
Min Max Factory setting
- [%] - [%] - [%]
p4835[0...4] Function generator free measurement function scaling / FG fr MeasFct scal
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-200.00000 [%] 200.00000 [%] 100.00000 [%]
r5005 Spindle file system status / File sys stat
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
01 Result data clamping cycle thresholds avail-
able
Yes No -
02 Result data clamping cycle counter avail-
able
Yes No -
03 Result data operating hours counter avail-
able
Yes No -
04 Result data temperature diagnostics avail-
able
Yes No -
05 Result data real time clock synchronization
available
Yes No -
06 Result data speed/torque matrix available Yes No -