Siemens SINAMICS S110 - p4716[0...1] Trace, bit mask trigger, trigger condition; Trace Trig_cond; p4717 Measuring function, number of averaging operations; Meas fct avg qty; p4718 Measuring function, number of stabilizing periods; MeasFct StabPerQty; r4719[0...1] Trace trigger index; Trace Trig_index

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-454
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only effective when p4710 = 6.
Description: Sets the trigger condition for bit mask trigger.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only effective when p4710 = 6.
Description: Sets the number of averaging operations for the measuring function.
Description: Sets the number of stabilizing periods for the measuring function.
Description: Displays the trigger index in the trace buffer. The trigger event occurred at this point.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only valid when p4705 = 4.
p4716[0...1] Trace, bit mask trigger, trigger condition / Trace Trig_cond
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 4294967295 0
p4717 Measuring function, number of averaging operations / Meas fct avg qty
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 255 0
p4718 Measuring function, number of stabilizing periods / MeasFct StabPerQty
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 255 0
r4719[0...1] Trace trigger index / Trace Trig_index
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -

Table of Contents