List of parameters
Parameter
1-597
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Note: This parameter is only supplied with actual values in the case of Safety Integrated Extended Functions. For Safety
Integrated Basic Functions (SBC, SS1, STO), the value is equal to zero.
Re bit 07:
An internal event is displayed if a STOP A ... F is active.
Description: Status signal for safety-relevant motion monitoring functions integrated in the drive.
Notice: Re bit 07:
An internal event is displayed if a STOP A ... F is active.
The signal state behaves in an opposite way to the PROFIsafe Standard.
Note: This parameter is only supplied with actual values in the case of Safety Integrated Extended Functions. For Safety
Integrated Basic Functions (SBC, SS1, STO), the value is equal to zero.
Description: Displays the changes of the safety message buffer. This counter is incremented every time that the safety message
buffer changes.
Recommend.: This is used to check whether the safety message buffer has been read out consistently.
Dependency: Refer to: r9747, r9748, r9749, p9752, r9753, r9754, r9755, r9756
Bit field: Bit Signal name 1 signal 0 signal FP
00 STO active Yes No -
01 SS1 active Yes No -
02 SS2 active Yes No -
03 SOS active Yes No -
04 SLS active Yes No -
05 SOS selected Yes No -
06 SLS selected Yes No -
07 Internal event Yes No -
12 SDI positive selected Yes No -
13 SDI neg selected Yes No -
14 ESR retract requested Yes No -
15 Safety message present Yes No -
r9742.0...15 CO/BO: SI Motion drive-integrated status signals (processor 2) / SI Mtn int st P2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 STO active Yes No -
01 SS1 active Yes No -
02 SS2 active Yes No -
03 SOS active Yes No -
04 SLS active Yes No -
07 Internal event No Yes -
09 Active SLS stage bit 0 Set Not set -
10 Active SLS stage bit 1 Set Not set -
11 SOS selected Yes No -
12 SDI pos active Yes No 2861
13 SDI neg active Yes No 2861
15 SSM (speed below limit value) Yes No 2860
r9744 SI message buffer changes, counter / SI msg_buffer chng
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -