Fig. 2-74 2800 – Basic Functions, parameter manager
- 2800 -
Function diagram
87654321
fp_2800_98_eng.vsd
DO: SERVO
SINAMICS S110Safety Integrated - Basic Functions, Parameter manager
Change safety parameters
p9601 = 0
[2810.3]
SI password input
p9761
Reset safety parameters
Inhibit safety functions
x
2 ms
26.04.11 V04.04.00
p9801 = 0
[2810.3]
Safety parameters
p9601 ... p9899
can be reset to the
factory settings via
p0970, p3900
Safety parameters
p9601 ... p9899
can be changed
SI password new
p9762
SI ackn password
p9763
Safety commissioning mode
[2802.1][2804.1]2804.3][2810.3]
--> select STO
Safety parameterizing enable
y
<1>
<1>
Effective password
=
Enter password
=
SET
y = x
Safety parameters
p9601 ... p9899
are valid
=
<1>
<1>
<1> Comparator, refer to [1021]
<2> Analog signal memory, refer to [1021]
<3> The target checksum must be equal to the actual checksum.
p9899
SI set_checksum P2
r9898
SI act_checksum P2
SI set_checksum P1
p9799
SI act_checksum P1
r9798
<3>
p0010 95
Exit safety
commissioning mode
=
Checksum check
for safety
parameters
&
& &
<2>
Safety Integrated commissioning
p0010 = 95
<3>