EasyManua.ls Logo

Siemens SINAMICS S110 - r2705 CO: Reference angle; Reference angle; r2706 CO: Reference temp; Reference temp; r2707 CO: Reference acceleration; Ref accel

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-416
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Note: This parameter provides the numerical value of the reference quantity p2004 in the currently selected unit as a con-
nector output for interconnection with Drive Control Chart (DCC). The numerical value can be adopted unchanged
from this connector output in DCC.
The reference power is calculated as follows:
- 2 * Pi * reference speed / 60 * reference torque (motor)
- reference voltage * reference current * root(3) (infeed)
Description: Connector output of the reference quantity for angles p2005.
All angles specified as relative value are referred to this reference quantity. The reference quantity in this parameter
corresponds to 100% or 4000 hex or 4000 0000 hex.
This parameter has the unit degree.
Dependency: Refer to: p2005
Note: This parameter provides the numerical value of the reference quantity p2005 as a connector output for interconnec-
tion with Drive Control Chart (DCC). The numerical value can be adopted unchanged from this connector output in
DCC.
Description: Connector output of the reference quantity for temperatures.
All temperatures specified as relative value are referred to this reference quantity. The reference quantity in this
parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
This parameter has the unit degree Celsius.
Note: This parameter provides the numerical value of the reference quantity for the temperature as a connector output for
interconnection with Drive Control Chart (DCC). The numerical value can be adopted unchanged from this connec-
tor output in DCC.
Description: Connector output of the reference quantity for accelerations p2007.
All acceleration rates specified as relative value are referred to this reference quantity. The reference quantity in
this parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
The unit of this parameter is the same as the unit selected for p2007.
Dependency: r0108.12, p0505
Refer to: p2007
Note: This parameter provides the numerical value of the reference quantity p2007 as a connector output for interconnec-
tion with Drive Control Chart (DCC). The numerical value in the currently selected unit can be adopted unchanged
from this connector output in DCC.
r2705 CO: Reference angle / Reference angle
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r2706 CO: Reference temp / Reference temp
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r2707 CO: Reference acceleration / Ref accel
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -