EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-181 8575 - Motor Data Sets (MDS)

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function diagrams
Data sets
2-954
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-181 8575 – Motor Data Sets (MDS)
- 8575 -
Function diagram
87654321
fp_8575_98_eng.vsd
DO: SERVO
SINAMICS S110
03.07.08 V04.04.00
Data sets - Motor Data Sets (MDS)
4000.00 μs
Motor selection
r0830.0
r0830
r0830.1
r0830.2
r0830.3
r0830.15
DO
DO
Feedback signal, contactor 0
p0831[0]
Feedback signal, contactor 1
p0831[1]
Feedback signal, contactor 2
p0831[2]
DI
DI
Feedback signal, contactor 3
p0831[3]
DI
Feedback signal, contactor 15
p0831[15]
DI
r0832.0
r0832
Mot_chng fdbk ZSW
r0832.1
r0832.2
r0832.3
r0832.15
Motor
Module
K2
K1
~
M1
3
K1
K1H
K2
~
M2
3
K2
K2H
K1
K1H K2H
0 V
Mot_chng fdbk sig
p0828[C]
p0833.0 (0)
0
1
0
1
Application
Pulse cancellation
MDS1
MDS0
p0826[0] Motor number
p0827[0] Bit number
MDS selected
r0838[0]
MDS effective
r0049[0]
p0833.1 (0)
Drive
Application
Drive
Request
pulse enable
Application
Motor changeover
<1> The following applies for the changeover of motor data sets:
The thermal motor model of motors with the same motor number is identical.
An unequal bit number means that the motor must be changed over.
<1>
DI
1
0
Copy MDS, source
p0139[0] (0)
Copy MDS, target
p0139[1] (0)
Copy MDS, start
p0139[2] (0)
DDS (Drive Data Set)
p0186[D] (MDS number)
p0187[D] (enc 1 EDS number)
MDS_chngov ZSW
r0835.0
r0835
(0)
p0820[C]
MDS count
p0130 (1)
p0188[D] (Enc 2 EDS number)

Table of Contents

Other manuals for Siemens SINAMICS S110