SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the measuring time for a falling edge at the digital input for the "central measuring probe evaluation" func-
tion.
The measuring time is specified as 16-bit value with a resolution of 0.25 µs.
r0687[0]: Measuring time, falling edge measuring probe 1
r0687[1]: Measuring time, falling edge measuring probe 2
r0687[2]: Measuring time, falling edge measuring probe 3
r0687[3]: Measuring time, falling edge measuring probe 4
r0687[4]: Measuring time, falling edge measuring probe 5
r0687[5]: Measuring time, falling edge measuring probe 6
r0687[6]: Measuring time, falling edge measuring probe 7
r0687[7]: Measuring time, falling edge measuring probe 8
Description: Displays the status word for the function "central measuring probe evaluation".
r0687[0...7] CO: Central measuring probe, measuring time falling edge / CenMeas t_meas 1/0
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0688 CO: Central measuring probe, status word display / Cen meas ZSW disp
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Digital input, measuring probe 1 High Low -
01 Digital input, measuring probe 2 High Low -
02 Digital input, measuring probe 3 High Low -
03 Digital input, measuring probe 4 High Low -
04 Digital input, measuring probe 5 High Low -
05 Digital input, measuring probe 6 High Low -
06 Digital input, measuring probe 7 High Low -
07 Digital input, measuring probe 8 High Low -
08 Sub-sampling, measuring probe 1 High Low -
09 Sub-sampling, measuring probe 2 High Low -
10 Sub-sampling, measuring probe 3 High Low -
11 Sub-sampling, measuring probe 4 High Low -
12 Sub-sampling, measuring probe 5 High Low -
13 Sub-sampling, measuring probe 6 High Low -
14 Sub-sampling, measuring probe 7 High Low -
15 Sub-sampling, measuring probe 8 High Low -