EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-79 2814 - Basic Functions, SBC (Safe Brake Control)

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function diagrams
Safety Integrated
2-840
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-79 2814 – Basic Functions, SBC (Safe Brake Control)
- 2814 -
Function diagram
87654321
DO: SERVO
SINAMICS S110
14.09.10 V04.04.00
Safety Integrated - Basic Functions, SBC (Safe Brake Control)
2 ms
Control Unit (Processor 1)
Power Module (Processor 2)
PM-IF
M
~
BR1*
BR2
BR_DIAG
BR1
BR2*
+24 V
BR1
BR2
1 = Transistor conductive
Upper gating control channel
Lower gating control channel
BR+
<1>
<1>
M
~
Safety Logic CU (P1)
(Implementation and
monitoring of brake control)
BR1
1
&
> 0
Safety enable p9801
Enable SBC p9802
Enable signals for SBC P2
Causes for "close brake"
From the STO
shutdown paths
[2810.6]
0 = STO_P1
0 = STO_P2
DIAG_U
DIAG_L
Safety fault
[2802.8]
1 = STOP A
&
&
Enable signals for SBC P1
> 0
Safety enable p9601
Enable SBC p9602
0 = "SBC selected"
F30630
"Incorrect safety brake control, P2"
1 = Fault, brake control
0 = "SBC requested"
0 = "SBC requested"
1 = "SBC enabled"
1
F07930 "Incorrect brake control"
F01630 "Incorrect safety brake control, P1"
1 = "Fault, brake control"
<1> Both transistors
conductive
--> 24 V on the brake
--> Brake opened
The BR+ and BR-
outputs are only
available for compact
drive units.
1 = "SBC enabled"
0 = "SBC selected"
Diagnostic signal
BR2*
1
1 = SBC
requested
r9872.4
[2804.5]
1
1 = SBC
requested
r9772.4
2804.2]
BR1*
BR_DIAG
Causes for "safely close brake"
From the STO
Shutdown paths
[2810.6]
0 = STO_P1
0 = STO_P2
DIAG_U
DIAG_L
Safety fault
[2802.8]
1 = STOP A
&
0 = Pulses
canceled
[2810.7]
BR_DIAG [2802.1]
M
BR-
1
0
2 ms
= 1
= 1
Close "normal" brake from the basic brake control [2701.8]
Close "normal" brake from the extennded brake control [2711.8]
0 = Pulses
cancelled
[2810.7]
fp_2814_98_eng.vsd
&
<2> Not if:
p9602 = p9802 = 0
and p1278 = 1
<2>
<2>
<2>
<2>
Safety Logic PM (P2)
(Implementation and
monitoring of brake control)
SBC: Safe Brake Control
(Sichere Bremsenansteuerung)