EasyManua.ls Logo

Siemens SINAMICS S110 - Fig. 2-156 7232 - PDE (ON delay), PDF (OFF delay)

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Free function blocks (FBLOCKS)
Function diagrams
2-925
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-156 7232 – PDE (ON delay), PDF (OFF delay)
- 7232 -
Function diagram
87654321
fp_7232_98_eng.vsd
DO: All Objects
SINAMICS S110
06.12.11 V04.04.00
FBLOCKS - PDE (switch-in delay), PDF (switch-out delay)
PDE 0 run-time group
p20161 (9999)
PDE 0 run sequence
p20162 (430)
PDE 1 run-time group
p20166 (9999)
PDE 1 run sequence
p20167 (440)
PDF 1 run-time group
p20176 (9999)
PDF 1 run sequence
p20177 (470)
PDF 0 run-time group
p20171 (9999)
PDF 0 run sequence
p20172 (460)
PDE 1
PDE 0
PDF 1
PDF 0
IQ
IQ IQ
IQ
(0)
PDE 0 input pulse I
p20158
(0)
PDE 1 input pulse I
p20163
(0)
PDF 1 input pulse I
p20173
(0)
PDF 0 input pulse I
p20168
PDF 0 output Q
r20170
PDF 1 output Q
r20175
PDE 1 output Q
r20165
PDE 0 output Q
r20160
PDE 0 pulse delay time in ms
0.00...60000.00
p20159 (0.00)
PDE 1 pulse delay time in ms
0.00...60000.00
p20164 (0.00)
PDF 0 pulse extension time in ms
0.00...60000.00
p20169 (0.00)
PDF 1 pulse extension time in ms
0.00...60000.00
p20174 (0.00)
T
T
T
T
T0 0T
0TT0