Parameter
List of parameters
1-148
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Notice: Terminal DO 16 is used for Safety Extended Functions as soon as this is enabled using p9601 and assuming that it
is not controlled via PROFIsafe.
The signal source set in p0746 is then no longer output at terminal DO 16.
Note: Inversion using p0748 has been taken into account.
DI/DO: Bidirectional Digital Input/Output
Description: Setting to invert the signals at the digital outputs.
Notice: If telegram 39x is set via p0922 in SINAMICS Integrated, the inversion of the output has no effect.
Note: DI/DO: Bidirectional Digital Input/Output
Description: Displays the actual input voltage at the analog input.
Note: AI: Analog Input
Description: Sets the smoothing time constant of the 1st-order low pass filter for the analog input.
Note: AI: Analog Input
Bit field: Bit Signal name 1 signal 0 signal FP
08 DI/DO 8 (X132.1) High Low -
09 DI/DO 9 (X132.2) High Low -
10 DI/DO 10 (X132.3) High Low -
11 DI/DO 11 (X132.4) High Low -
16 DO 16 (X131.5) High Low -
p0748 CU, invert digital outputs / CU DO inv
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 0000
0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
08 DI/DO 8 (X132.1) Inverted Not inverted 2030
09 DI/DO 9 (X132.2) Inverted Not inverted 2030
10 DI/DO 10 (X132.3) Inverted Not inverted 2031
11 DI/DO 11 (X132.4) Inverted Not inverted 2031
16 DO 16 (X131.5) Inverted Not inverted 2032
r0752 CO: CU analog input, input voltage actual / CU AI U_input act
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 2040
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
p0753 CU analog input smoothing time constant / CU AI T_smooth
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dynamic index: - Func. diagram: 2040
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.0 [ms] 1000.0 [ms] 0.0 [ms]