List of parameters
Parameter
1-427
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Sets the synchronization source/technique.
Value: 0: PROFIBUS
1: PROFINET
2: PPI
3: PROFINET PTP
Description: Sets the signal source for the PING event to set the UTC time.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Displays the last synchronization deviation that was determined.
r3108[0]: Milliseconds
r3108[1]: Days
Description: Sets the tolerance window for time synchronization.
When this tolerance window is exceeded, an appropriate alarm is output.
Dependency: Refer to: A01099
p3103 RTC synchronization source / RTC sync_source
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 3 0
p3104 BI: RTC real time synchronization PING / RTC PING
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
r3108[0...1] RTC last synchronization deviation / RTC sync_dev
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p3109 RTC real time synchronization, tolerance window / RTC sync tol
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 1000 [ms] 100 [ms]