Internal control/status words
Function diagrams
2-819
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Fig. 2-61 2526 – Status word, closed-loop control
- 2526 -
Function diagram
87654321
fp_2526_98_eng.vsd
DO: SERVO
SINAMICS S110
30.10.08 V04.04.00
Internal control/status words - Status word, closed-loop control
1
2
4
Reserved
Meaning
1 = De-magnetization completed
Reserved
1 = Magnetization completed
Reserved
0
Bit No.
7
Status word closed-loop control
8
9
11
1 = Field weakening active
Reserved
Reserved
1 = Vdc_max controller active14
1 = Vdc_min controller active15
r0056
ZSW closed-loop control
r0056.14
r0056.15
r0056.1
r0056.4
r0056.8
3 Reserved
5 Reserved
6 Reserved
12 Reserved
13 Reserved
10 Reserved
Refer to [1020.7]
250 s
[2701.1][2707.1]
[5650.8]
[5650.8]
[6722.6][6725.6]
[6722.3][6725.4]