EasyManua.ls Logo

Siemens SINAMICS S110 - r0484[0...2] CO: Redundant coarse encoder position + CRC Gn_XIST1; Enc red pos+CRC; r0487[0...2] Diagnostic encoder control word Gn_STW; Enc Gn_STW

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-120
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
4097: Abort, reference mark search due to an initialization error.
4098: Abort, flying measurement due to an initialization error.
4099: Abort, reference mark search due to a measuring error.
4100: Abort, flying measurement due to a measuring error.
Description: Displays the redundant coarse encoder position including CRC (Cyclic Redundancy Check).
Upper 16 bits:
CRC over the redundant coarse encoder position.
Lower 16 bits:
Redundant coarse encoder position.
On an SMx Sensor Module, the encoder coarse position count direction is opposite to r0482 (encoder actual value
Gn_XIST1). The value contains 2 bit fine resolution.
With a DRIVE-CLiQ encoder, the encoder coarse position count direction is the same as r0482. The encoder
coarse position contains 9 valid bits and no bits for fine resolution.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency: The values are valid when the safety position actual value sensing is activated (p0430.19 = 1).
Refer to: p0430
Note: This absolute value does not change, contrary to r0482, when de-selecting the function "parking axis".
Description: Displays the encoder control word Gn_STW according to PROFIdrive for diagnostics.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Notice: Information on Gn_STW/Gn_ZSW should be taken from the corresponding product documentation.
Note: The signal source for the encoder control word is set with p0480.
r0484[0...2] CO: Redundant coarse encoder position + CRC Gn_XIST1 / Enc red pos+CRC
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0487[0...2] Diagnostic encoder control word Gn_STW / Enc Gn_STW
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 1580, 4704,
4720, 4740
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Request function 1 Yes No -
01 Request function 2 Yes No -
02 Request function 3 Yes No -
03 Request function 4 Yes No -
04 Request command bit 0 Yes No -
05 Request command bit 1 Yes No -
06 Request command bit 2 Yes No -
07 Flying measurement mode/search for refer-
ence mark
Flying measurement Reference marks -
13 Request absolute value cyclic Yes No -
14 Request parking encoder Yes No -
15 Request acknowledge encoder fault Yes No -

Table of Contents