Description: Displays the magnetizing currents of the identified saturation characteristic.
The values are referred to r0331.
Dependency: Refer to: p1959, p1960, r1963
Note: The saturation characteristic consists of the value pairs from p1962 and p1963 with the same index.
Description: Displays the stator flux of the identified saturation characteristic.
The values are referred to the stator flux at the magnetizing current (r0331).
Dependency: Refer to: p1959, p1960, r1962
Note: The saturation characteristic consists of the value pairs from p1962 and p1963 with the same index.
Description: Displays the identified moment of inertia.
Dependency: IEC drives (p0100 = 0): unit kg m^2
NEMA drives (p0100 = 1): unit lb ft^2
Refer to: p0341, p0342, p1498, p1959, p1960
Description: Index 0:
Rotating motors: Displays the identified encoder pulse number (per revolution).
Linear motors: Encoder pulse number per meter. Grid division = 1/p1973 [meter].
Index 1:
Rotating motors: No significance.
Linear motors: Identified grid division in nm.
Index: [0] = Rotating motor encoder pulse number
[1] = Linear motor, grid division in nm
r1962[0...9] Saturation characteristic magnetizing current identified / Sat_char I_mag
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r1963[0...9] Saturation characteristic stator flux identified / Sat_char flux
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r1969 Moment of inertia identified / M_inertia ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: 25_1 Unit selection: p0100
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- [kgm²] - [kgm²] - [kgm²]
r1973[0...1] Encoder, pulse number identified / Pulse No. ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Integer32 Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- - -