Parameter
List of parameters
1-436
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency: Refer to: r3925
Description: Displays the characteristics (A5E number and versions) of the power unit.
[0]: A5E number xxxx (A5Exxxxyyyy)
[1]: A5E number yyyy (A5Exxxxyyyy)
[2]: File version (logistic)
[3]: File version (fixed data)
[4]: File version (calib data)
Description: For service personnel only.
Description: Displays the status word for the drive unit.
13 p1717 accepted Yes No -
18 p0316 accepted Yes No -
19 p0317 accepted Yes No -
20 p0327 accepted Yes No -
21 p0328 accepted Yes No -
22 p0341 accepted Yes No -
23 kT characteristic parameter accepted Yes No -
24 p0348 accepted Yes No -
r3930[0...4] Power unit EEPROM characteristics / PU characteristics
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p3950 Service parameter / Serv. par.
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: C1, U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r3974 Drive unit status word / Drv_unit ZSW
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Software reset active Yes No -
01 Writing of parameters disabled as parame-
ter save in progress
Yes No -
02 Writing of parameters disabled as macro is
running
Yes No -