Siemens SINAMICS S110 - r4742[0...16383] Trace 0 trace buffer signal 2 floating point; Trace 0 trace sig2; r4743[0...16383] Trace 0 trace buffer signal 3 floating point; Trace 0 trace sig3; r4744[0...16383] Trace 0 trace buffer signal 4 floating point; Trace 0 trace sig4; r4745[0...16383] Trace 0 trace buffer signal 5 floating point; Trace 0 trace sig5

Siemens SINAMICS S110
1288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
List of parameters
1-460
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description: Displays the trace buffer (record buffer) for trace 0 and signal 2.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 3.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 4.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 5.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 6.
Dependency: Refer to: r4740, p4795
r4742[0...16383] Trace 0 trace buffer signal 2 floating point / Trace 0 trace sig2
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4743[0...16383] Trace 0 trace buffer signal 3 floating point / Trace 0 trace sig3
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4744[0...16383] Trace 0 trace buffer signal 4 floating point / Trace 0 trace sig4
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4745[0...16383] Trace 0 trace buffer signal 5 floating point / Trace 0 trace sig5
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4746[0...16383] Trace 0 trace buffer signal 6 floating point / Trace 0 trace sig6
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0