Description: Detection of the main components of the drive object selected via the index.
Description: Displays the version of the EPROM data of the power unit.
Dependency: Refer to: r0147
Note: For parallel circuit configurations, the parameter index is assigned to a power unit.
Description: Displays the firmware version of the power unit.
Dependency: Refer to: r0018, r0148, r0197, r0198
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
For parallel circuit configurations, the parameter index is assigned to a power unit.
Description: Sets the number of Motor Data Sets (MDS).
Description: The motor data set is assigned to a motor using this parameter.
This unique component number is assigned when parameterizing the topology.
p0124[0...23] Main component detection using LED / M_comp detect LED
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
r0127[0...n] Power unit version EPROM data / PU EPROM version
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: PDS Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0128[0...n] Power unit, firmware version / PU FW version
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: PDS Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p0130 Number of Motor Data Sets (MDS) / MDS count
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C1(3) Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: 8575
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 2 1
p0131[0...n] Motor component number / Mot comp_no
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed: C1(4) Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 199 0