Parameter
Overview of parameters
1-14
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
BICO: Full parameter name/Abbreviated name
The following abbreviations can appear in front of the parameter name:
Drive object (function module)
A drive object (DO) is an independent, "self-contained" functional unit that has its
own parameters and, in some cases, faults and alarms.
When carrying out commissioning using the commissioning software, you can
select/deselect additional functions and their parameters by activating/deactivat-
ing function modules accordingly.
The parameter list specifies the associated drive object and function module for
each individual parameter.
Note:
The parameter list can contain parameters that are not visible in the expert lists
of the particular commissioning software (e.g. parameters for trace functions).
• BI: Binector Input
This parameter is used for selecting the source of a digital signal.
• BO: Binector Output
This parameter is available as a digital signal for interconnection
with other parameters.
• CI: Connector Input
This parameter is used for selecting the source of an “analog” sig-
nal.
• CO: Connector Output
This parameter is available as an “analog” signal for interconnec-
tion with other parameters.
• CO/BO: Connector/Binector Output
This parameter is available as an "analog" and digital signal for
interconnection with other parameters.
Note:
A connector input (CI) cannot be just interconnected with any connector output
(CO, signal source).
When interconnecting a connector input using the commissioning software, only
the corresponding possible signal sources are listed.
Note:
References: /FH3/ SINAMICS S110 Function Manual