Parameter
Overview of parameters
1-18
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Data type
The information on the data type can consist of the following two items (separated
by a slash):
First item
Data type of the parameter
Second item (for binector or connector input only)
Data type of the signal source to be interconnected (binector/connector out-
put)
Parameters can have the following data types:
Depending on the data type of the BICO input parameter (signal sink) and BICO
output parameter (signal source), the following combinations are possible when
BICO interconnections are established:
I8 Integer8 8-bit integer
I16 Integer16 16-bit integer
I32 Integer32 32-bit integer
U8 Unsigned8 8 bits without sign
U16 Unsigned16 16 bits without sign
U32 Unsigned32 32 bits without sign
Float FloatingPoint32 32-bit floating point number
Table 1-2 Possible combinations of BICO interconnections
BICO input parameter
CI parameter BI parameter
BICO output parameter Unsigned32/
Integer16
Unsigned32/
Integer32
Unsigned32/
FloatingPoint32
Unsigned32/
Binary
CO: Unsigned8 x x
CO: Unsigned16 x x
CO: Integer16 x x
CO: Unsigned32 x x
CO: Integer32 x x
CO: FloatingPoint32 x x x
1
BO: Unsigned8 x
BO: Unsigned16 x
Legend: x: BICO interconnection permitted
–: BICO interconnection not permitted
1 Exception:
BICO input parameters with data type "Unsigned32/FloatingPoint32" can also be interconnected with the following
BICO output parameters, despite the fact that these are not of the "FloatingPoint32" data type:
CO: r2050, CO: r2060