Parameters for data sets
Parameter
1-737
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
p1441[0...n] Actual speed smoothing time / n_act T_smooth
p1451[0...n] Speed actual value smoothing time sensorless / n_act t_sm SL
p1456[0...n] Speed controller P gain adaptation lower starting point / n_ctrl AdaptKpLow
p1457[0...n] Speed controller P gain adaptation upper starting point / n_ctrl AdaptKp up
p1458[0...n] Adaptation factor, lower / Adapt_factor lower
p1459[0...n] Adaptation factor, upper / Adapt_factor upper
p1460[0...n] Speed controller P gain adaptation speed, lower / n_ctrl Kp n lower
p1461[0...n] Speed controller Kp adaptation speed, upper scaling / n_ctrl Kp n upper
p1462[0...n] Speed controller integral time adaptation speed lower / n_ctrl Tn n lower
p1463[0...n] Speed controller Tn adaptation speed, upper scaling / n_ctrl Tn n upper
p1464[0...n] Speed controller adaptation speed, lower / n_ctrl n lower
p1465[0...n] Speed controller adaptation speed, upper / n_ctrl n upper
p1470[0...n] Speed controller encoderless operation P-gain / n_ctrl SLVC Kp
p1472[0...n] Speed controller encoderless operation integral time / n_ctrl SLVC Tn
p1494[0...n] Speed controller integrator feedback time constant / n_ctr integ_fdbk T
p1498[0...n] Load moment of inertia / Load mom of inert
p1517[0...n] Accelerating torque smoothing time constant / M_accel T_smooth
p1520[0...n] CO: Torque limit upper/motoring / M_max upper/mot
p1521[0...n] CO: Torque limit lower/regenerative / M_max lower/regen
p1524[0...n] CO: Torque limit upper/motoring scaling / M_max up/mot scal
p1525[0...n] CO: Torque limit lower/regenerative scaling / M_max low/gen scal
p1530[0...n] Power limit motoring / P_max mot
p1531[0...n] Power limit regenerative / P_max gen
p1532[0...n] CO: Torque limit offset / M_max offset
p1578[0...n] Flux reduction flux decrease smoothing time / Flux red dec t_sm
p1579[0...n] Flux reduction flux build-up smoothing time / Flux red up t_sm
p1581[0...n] Flux reduction factor / Flux red factor
p1585[0...n] Flux actual value, smoothing time / Flux actVal T_smth
p1590[0...n] Flux controller P gain / Flux controller Kp
p1592[0...n] Flux controller integral time / Flux controller Tn
p1612[0...n] Current setpoint, open-loop control, encoderless / I_setCtrEncoderl
p1656[0...n] Activates current setpoint filter / I_setp_filt act
p1657[0...n] Current setpoint filter 1 type / I_set_filt 1 Typ
p1658[0...n] Current setpoint filter 1 denominator natural frequency / I_set_filt 1 fn_n
p1659[0...n] Current setpoint filter 1 denominator damping / I_set_filt 1 D_n
p1660[0...n] Current setpoint filter 1 numerator natural frequency / I_set_filt 1 fn_z
p1661[0...n] Current setpoint filter 1 numerator damping / I_set_filt 1 D_z
p1662[0...n] Current setpoint filter 2 type / I_set_filt 2 Typ
p1663[0...n] Current setpoint filter 2 denominator natural frequency / I_set_filt 2 fn_n
p1664[0...n] Current setpoint filter 2 denominator damping / I_set_filt 2 D_n
p1665[0...n] Current setpoint filter 2 numerator natural frequency / I_set_filt 2 fn_z
p1666[0...n] Current setpoint filter 2 numerator damping / I_set_filt 2 D_z
p1701[0...n] Current controller reference model dead time / I_ctrRefMod t_dead
p1715[0...n] Current controller P gain / I_ctrl Kp
p1717[0...n] Current controller integral-action time / I_ctrl Tn
p1752[0...n] Motor model changeover speed operation with encoder / MotMod n_chgov enc
p1755[0...n] Motor model changeover speed encoderless operation / MotMod n_chgSnsorl
p1800[0...n] Pulse frequency setpoint / Pulse freq setp
p1821[0...n] Dir of rot / Dir of rot
p2140[0...n] Hysteresis speed 2 / n_hysteresis 2
p2141[0...n] Speed threshold 1 / n_thresh val 1
p2142[0...n] Hysteresis speed 1 / n_hysteresis 1
p2149[0...n] Monitoring configuration / Monit config