Defaults Disabled
Command Modes CONFIGURATION
Command History
Version 8.3.11.4 Introduced on the Z9000 to replace the enable xfp-power-
updates command.
Version 8.3.10.0 Replacement command for the S4810 only. Replaces the enable 
xfp-power-updates command.
Usage 
Information
Use this command to enable polling and to configure the polling frequency.
enable xfp-power-updates
Enable 10–gigabit small form-factor pluggable (XFP) power updates for SNMP.
C-Series, E-Series, S-Series
Syntax
enable xfp-power-updates interval seconds
Parameters
interval 
seconds
Enter the keyword interval followed by the polling interval in 
seconds. Range: 120 to 6000 seconds. Default: 300 seconds (5 
minutes).
Defaults Disabled
Command Modes CONFIGURATION
Command History
Version 8.3.11.4 Deprecated command for Z9000 only. Replaced by the enable 
optic-info-update interval command to update 
information on temperature and power monitoring in the SNMP MIB.
Version 8.3.10.0 Deprecated command for the S4810 only. Replaced by the enable 
optic-info-update interval command to update 
information on temperature and power monitoring in the SNMP MIB.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series and E-Series.
Usage 
Information
The chassis MIB contains the entry chSysXfpRecvPower in the chSysPortTable 
table. Periodically, IFA polls the XFP power for each of the ports and sends the values to IFM 
where it is cached.
Use this command to enable polling and to configure the polling frequency.
108