Related
Commands
logging – enables the logging to another device.
logging on – enables logging.
show logging
Display the logging settings and system messages logged to the internal buffer of the switch.
C-Series, E-Series, S-Series, Z-Series
Syntax
show logging [number | history [reverse][number] | reverse
[number] | summary]
Parameters
number
(OPTIONAL) Enter the number of message to be displayed on the
output. The range is 1 to 65535.
history (OPTIONAL) Enter the keyword history to view only information in
the Syslog history table.
reverse (OPTIONAL) Enter the keyword reverse to view the Syslog
messages in FIFO (first in, first out) order.
summary (OPTIONAL) Enter the keyword summary to view a table showing
the number of messages per type and per slot. Slots *7* and *8*
represent RPMs.
Command Modes
• EXEC
• EXEC Privilege
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
Example (Partial)
FTOS#show logging
Syslog logging: enabled
Console logging: level debugging
Monitor logging: level debugging
Buffer logging: level debugging, 5604 Messages Logged,
Size (524288 bytes)
Trap logging: level informational
Oct 8 09:25:37: %RPM1:RP1 %BGP-5-ADJCHANGE: Connection with
neighbor 223.80.255.254 closed. Hold time
expired
Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Neighbor
192.200.13.2 Up
Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Neighbor
192.1.1.13 Up
Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Neighbor 1.1.14.2
1391