Example (EDS/
PVID)
FTOS#show spanning-tree pvst vlan 2 interface gigabitethernet 
1/0
GigabitEthernet 1/0 of VLAN 2 is PVID_INC discarding
Edge port:no (default) port guard :none (default)
Link type: point-to-point (auto) bpdu filter:disable (default)
Bpdu guard :disable (default)
Bpdus sent 1, received 0
Interface Designated
Name   PortID   Prio Cost  Sts Cost Bridge ID       PortID
---------------------------------------------------------
Gi 1/0 128.1223 128 20000 EDS 0 32768 0001.e800.a12b 128.1223
Example (Guard)
FTOS#show spanning-tree pvst vlan 5 guard
Interface
Name   Instance Sts        Guard type
-----------------------------------
Gi 0/1 5       INCON(Root) Rootguard
Gi 0/2 5       FWD         Loopguard
Gi 0/3 5       EDS(Shut)   Bpduguard
Related 
Commands
spanning-tree pvst – configure PVST+ on an interface.
spanning-tree pvst
Configure a PVST+ interface with one of these settings: edge port with optional bridge port data unit (BPDU) guard, port 
disablement if an error condition occurs, port priority or cost for a VLAN range, loop guard, or root guard.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
spanning-tree pvst {edge-port [bpduguard [shutdown-on-
violation]] | err-disable | vlan vlan-range {cost number | 
priority value} | loopguard | rootguard}
Parameters
edge-port Enter the keywords edge-port to configure the interface as a 
PVST+ edge port.
bpduguard
Enter the keyword portfast to enable Portfast to move the 
interface into Forwarding mode immediately after the root fails.
Enter the keyword bpduguard to disable the port when it receives a 
BPDU.
shutdown-on-
violation
(OPTIONAL) Enter the keywords shutdown-on-violation to 
hardware disable an interface when a BPDU is received and the port 
is disabled.
err-disable Enter the keywords err-disable to enable the port to be put into 
the error-disable state (EDS) if an error condition occurs.
1173