Command History
Version 8.1.1.2 Introduced on the E-Series ExaScale E600i.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.9.1.0 Introduced VRF on the E-Series.
Version 7.5.1.0 Introduced on the C-Series.
pre-Version
6.2.1.1
Introduced on the E-Series.
Usage
Information
Use this command to clear Layer 3 CAM inconsistencies.
CAUTION: Executing this command causes traffic disruption.
Related
Commands
show ip fib linecard – shows FIB entries.
clear ip fib stack-unit
Clear all FIB entries in the specified stack unit (use this command with caution, refer to
Usage Information
below.)
S-Series, Z-Series
Syntax
clear ip fib stack-unit unit-number
Parameters
unit-number
Enter the number of the stack unit.
The range is 0 to 7.
Command Modes EXEC
Command History
9.0.0.0 Introduced on the Z9000.
Usage
Information
Use this command to clear Layer 3 CAM inconsistencies.
CAUTION: Executing this command causes traffic disruption.
Related
Commands
show ip fib stack-unit – Shows FIB entries on a specified stack-unit.
775