Defaults 30 seconds
Command Modes INTERFACE
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the C-Series and S-Series.
Version 7.4.1.0 Introduced on the E-Series.
dot1x tx-period
Configure the intervals at which EAPOL PDUs are transmitted by the Authenticator PAE.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
dot1x tx-period seconds
To return to the default, use the no dot1x tx-period command.
Parameters
seconds
Enter the interval time, in seconds, that EAPOL PDUs are transmitted.
The range is 1 to 31536000 (1 year). The default is 30.
Defaults 30 seconds
Command Modes INTERFACE
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the C-Series and S-Series.
Version 7.4.1.0 Introduced on the E-Series.
show dot1x interface
Display the 802.1X information on an interface.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
show dot1x interface interface
Parameters
interface
Enter one of the following keywords and slot/port or number
information:
• For a Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed by the slot/port information.
• For a Fast Ethernet interface, enter the keyword
FastEthernet followed by the slot/ port information.
1322