Sending 5, 100-byte ICMP Echos to 172.31.1.255, timeout is 2 
seconds:
Reply to request 1 from 172.31.1.208 0 ms
Reply to request 1 from 172.31.1.216 0 ms
Reply to request 1 from 172.31.1.205 16 ms
::
Reply to request 5 from 172.31.1.209 0 ms
Reply to request 5 from 172.31.1.66 0 ms
Reply to request 5 from 172.31.1.87 0 ms
FTOS#
Example (IPv6)
FTOS#ping 100::1
Type Ctrl-C to abort.
Sending 5, 100-byte ICMP Echos to 100::1, timeout is 2 seconds:
!!!!!
Success rate is 100.0 percent (5/5), round-trip min/avg/max = 
0/0/0 (ms)
FTOS#
power-off
Turn off power to a selected line card or the standby (extra) switch fabric module (SFM).
C-Series, E-Series
Syntax
power-off {linecard number | sfm sfm-slot-id}
Parameters
linecard 
number
Enter the keyword linecard and a number for the line card slot 
number. For the C-Series, the range is 0 to 7. For the E-Series, the 
range is 0 to 13 on the E1200/E1200i, 0 to 6 on the E600/E600i, and 0 to 
5 on the E300.
sfm 
sfm-slot-id
Enter the keyword sfm by the slot number of the SFM to which you 
want to turn off power.
NOTE: This option is supported on the E-Series only.
Defaults Disabled.
Command Modes EXEC Privilege
Command History
Version 8.1.1.2 Introduced on the E-Series ExaScale E600i.
Version 8.1.1.0 Introduced on the E-Series ExaScale E1200i.
Version 7.5.1.0 Introduced on the C-Series.
E-Series Original command.
129