0 1 0 00:01:e8:0d:b7:3b LOCAL_DA 1e000
1 1 0 00:01:e8:0d:b7:3a LOCAL_DA 1e000
101 0 0 00:01:e8:00:04:00 SYSTEM_STATIC 01c05
102 0 0 01:80:00:00:00:00 SYSTEM_STATIC 01c05
103 0 0 01:00:0c:cc:cc:cc SYSTEM_STATIC 01c01
104 0 0 01:80:c2:00:00:02 SYSTEM_STATIC 01c02
105 0 0 01:80:c2:00:00:0e SYSTEM_STATIC 01c01
106 0 0 00:01:e8:0d:b7:68 SYSTEM_STATIC DROP
107 0 0 00:01:e8:0d:b7:67 SYSTEM_STATIC DROP
108 0 0 00:01:e8:0d:b7:66 SYSTEM_STATIC DROP
109 0 0 00:01:e8:0d:b7:65 SYSTEM_STATIC DROP
110 0 0 00:01:e8:0d:b7:64 SYSTEM_STATIC DROP
111 0 0 00:01:e8:0d:b7:63 SYSTEM_STATIC DROP
112 0 0 00:01:e8:0d:b7:62 SYSTEM_STATIC DROP
113 0 0 00:01:e8:0d:b7:61 SYSTEM_STATIC DROP
114 0 0 00:01:e8:0d:b7:60 SYSTEM_STATIC DROP
115 0 0 00:01:e8:0d:b7:5f SYSTEM_STATIC DROP
116 0 0 00:01:e8:0d:b7:5e SYSTEM_STATIC DROP
117 0 0 00:01:e8:0d:b7:5d SYSTEM_STATIC DROP
FTOS#
show cam mac stack-unit
Display the content addressable memory (CAM) size and the portions allocated for MAC addresses and for MAC ACLs.
S-Series
Syntax
show cam mac stack-unit unit_number port-set port-pipe count
[vlan vlan-id] [interface interface]
Parameters
stack-unit
unit_number
(REQUIRED) Enter the keyword linecard followed by a stack
member number to select the linecard for which to gather
information. The S-Series range is 0 to 1.
port-set
port-pipe
(REQUIRED) Enter the keywords port-set followed by a Port-Pipe
number to select the Port-Pipe for which to gather information. The
range is 0 or 1.
address
mac-
addr
(OPTIONAL) Enter the keyword address followed by a MAC
address in the nn:nn:nn:nn:nn:nn format to display information on that
MAC address.
dynamic (OPTIONAL) Enter the keyword dynamic to display only those MAC
addresses learned dynamically by the switch.
static (OPTIONAL) Enter the keyword static to display only those MAC
address specifically configured on the switch.
interface
interface
(OPTIONAL) Enter the keyword interface followed by the
interface type, slot and port information:
• For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed by the slot/port information.
930