Version 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to
7.8.1.0, names were up to 16 characters long.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
pre-Version
6.2.1.1
Introduced on the E-Series.
Usage
Information
You can assign one ACL (standard or extended ACL) to an interface.
NOTE: This command supports Loopback interfaces EE3 and EF series route processor
modules (RPMs). This command does not support Loopback interfaces ED series RPMs, C-
Series or S-Series Loopback interfaces.
When you apply an ACL that filters IGMP traffic, all IGMP traffic is redirected to the CPUs and
soft-forwarded, if required, in the following scenarios:
• on a Layer 2 interface - if a Layer 3 ACL is applied to the interface
• on a Layer 3 port or on a Layer 2/Layer 3 port
Related
Commands
ip access-list standard – configures a standard ACL.
ip access-list extended – configures an extended ACL.
ip control-plane egress-filter
Enable egress Layer 3 ACL lookup for IPv4 CPU traffic.
Z-Series, S4810
Syntax
ip control-plane egress-filter
Defaults Not enabled.
Command Modes EXEC Privilege
Command History
Version 8.3.11.1 Introduced on the Z9000.
show ip accounting access-list
Display the IP access-lists created on the switch and the sequence of filters.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
show ip accounting {access-list access-list-name | cam_count}
interface interface
Parameters
access-list-name
Enter the name of the ACL to be displayed.
cam_count
List the count of the CAM rules for this ACL.
interface
interface
Enter the keyword interface followed by the one of the following
keywords and slot/port or number information:
216