Version 7.8.1.0 Introduced on the S-Series.
show hardware stack-unit
Display the data plane or management plane input and output statistics of the designated component of the designated
stack member.
S-Series, Z-Series
Syntax
show hardware stack-unit stack-unit {cpu data-plane statistics
[stack-port 0-52] | cpu i2c statistics | cpu party-bus
statistics | cpu sata-interface statistics | drops [unit number
[port 0-27]] | stack-port 0-52 | ti-monitor | unit 0-1
{counters | details | port-stats [detail] | register}}
Parameters
stack-unit
stack-
unit
{command-
option}
Enter the keywords stack-unit to select a particular stack
member and then enter one of the following command options to
display a collection of data based on the option entered. The Z9000
range is 0 to 7.
cpu data-plane
statistics
Enter the keywords cpu data-plane statistics, optionally
followed by the keywords stack port and its number, 0 to 52, to
display the data plane statistics, which shows the High Gig (
Higig)
port raw input/output counter statistics to which the stacking module
is connected.
cpu i2c statistics Z9000 only: Enter the keywords cpu i2c statistics to display
active i2c address statistics.
cpu party-bus
statistics
Enter the keywords cpu party-bus statistics, to display
the Management plane input/output counter statistics of the pseudo
party bus interface.
cpu sata-
interface
statistics
Z9000 only: Enter the keywords cpu sata-interface
statistics to display the sata interface error counter statistics.
drops [unit
0-1
[port
0-27
| no]]
Enter the keyword drops to display internal drops on the selected
stack member. Optionally, use the keyword unit with 0 or 1 to
select port-pipe 0 or 1, and then use
port
0-27
to select a port on
that port-pipe.
stack-port
0-52
S-Series only: Enter the keywords stack-port and a stacking port
number to select a stacking port for which to display statistics.
unit
0-3
{counters
| details | port-
stats [detail] |
register}
Enter the keyword unit followed by 0 or 3 and then enter one of the
following keywords to troubleshoot errors on the selected port-pipe
and to give status on why a port is not coming up to register level:
counters, details, port-stats [detail], or register.
TI monitor S55 only: Enter the unit keyword to show information regarding the TI
register.
Defaults none