5 not present
6 not present
7 not present
8 not present
9 not present
10 not present
11 booting 53C down up ok
12 not present
13 not present
-- RPM Environment Status --
Slot Status Temp PEM0 PEM1 Voltage
-------------------------------------------------------
0 active 48C down up ok
1 not present
-- SFM Environment Status --
Slot Status Temp PEM0 PEM1
--------------------------------------------------------
0 active 49C up up
1 active 47C up up
2 active 46C up up
3 active 48C up up
4 active 52C up up
5 active 50C up up
6 active 47C up up
7 active 48C up up
8 active 47C up up
Example (E600)
FTOS#show environment fan
-- Fan Status --
Status Temp Fan1 Fan2 Fan3 Serial Num Version
------------------------------------------------------
up 29C 6000 RPM 7500 RPM 7500 RPM 0.0
FTOS#
Example (C300)
FTOS#show env fan
-- Fan Status --
-------------------------------------------------------
Tray 0
-------------------------------------------------------
FanNumber Speed Status
0 4170 up
1 4140 up
2 3870 up
3 4140 up
4 3870 up
5 3810 up
FTOS#
show environment (S-Series)
View S-Series system component status (for example, temperature or voltage).
S-Series, Z-Series
Syntax
show environment [all | fan | stack-unit unit-id | pem]
144