module power-off
Turn off power to a line card at next reboot.
C-Series, E-Series
Syntax
module power-off linecard number
Parameters
linecard
number
Enter the keyword linecard followed by the line card slot number.
The C-Series range is 0 to 7. The E-Series range is 0 to 13 on the
E1200/1200i, 0 to 6 on the E600/E600i, and 0 to 5 on the E300.
Defaults Not configured.
Command Modes CONFIGURATION
Command History
Version 8.1.1.2 Introduced on the E-Series ExaScale E600i.
Version 8.1.1.0 Introduced on the E-Series ExaScale E1200i.
Version 7.5.1.0 Introduced on the C-Series.
E-Series Original command
motd-banner
Enable a message of the day (MOTD) banner to appear when you log in to the system.
C-Series, E-Series, S-Series, Z-Series
Syntax
motd-banner
To disable the MOTD banner, use the no motd-banner command.
Defaults Enabled on all lines.
Command Modes LINE
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.1.1.0 Introduced on the E-Series ExaScale
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
E-Series Original command
125