show buffer-profile stack-unit
Displays the global buffer profile.
S4810, Z-Series
Syntax
show buffer-profile stack-unit stack unit number
Parameters
stack unit number
Enter the stack unit number. The range is 0 to 11. For the Z9000, only
stack-unit 0 is supported.
Defaults Dynamic
Command Modes CONFIGURATION
Command History
Version 8.3.11.4 Introduced on the Z9000.
Example (S4810)
FTOS#show buffer-profile stack-unit
Stack-Unit Current Buffer-Profile Next-Boot Buffer-Profile
---------- ---------------------- ------------------------
0 Default (Dynamic) Default (Dynamic)
1 Default (Dynamic) Default (Dynamic)
Example (Z9000)
FTOS#show buffer-profile stack-unit
Stack-Unit Current Buffer-Profile Next-Boot Buffer-Profile
---------- ---------------------- ------------------------
0 Default (Dynamic) Default (Dynamic)
show buffer-profile
Display the buffer profile that is applied to an interface.
C-Series, S-Series
Syntax
show buffer-profile {detail | summary} {csf | fp-uplink}
Parameters
detail Display the buffer allocations of the applied buffer profiles.
summary Display the buffer-profiles that are applied to line card port-pipes in
the system.
csf Display the Switch Fabric Processor buffer profiles that you have
applied to line card port-pipes in the system.
fp-uplink Display the Field Processor buffer profiles that you have applied to
line card port-pipes in the system.
Defaults none
Command Modes INTERFACE
Command History
Version 7.7.1.0 Introduced on the S-Series.
577