show alarms
View alarms for the route process module (RPM), switch fabric modules (SFMs), line cards, and fan trays.
C-Series, E-Series, S-Series, Z-Series
Syntax
show alarms [threshold]
Parameters
threshold (OPTIONAL) Enter the keyword threshold to display the
temperature thresholds set for the line cards, RPM, and SFMs.
Command Modes
• EXEC
• EXEC Privilege
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
E-Series Original command.
Example
FTOS# show alarms
-- Minor Alarms --
Alarm Type Duration
----------------------------------------------
RPM 0 PEM A failed or rmvd 7 hr, 37 min
SFM 0 PEM A failed or rmvd 7 hr, 37 min
SFM 1 PEM A failed or rmvd 7 hr, 37 min
SFM 2 PEM A failed or rmvd 7 hr, 37 min
SFM 3 PEM A failed or rmvd 7 hr, 37 min
SFM 4 PEM A failed or rmvd 7 hr, 37 min
SFM 5 PEM A failed or rmvd 7 hr, 37 min
SFM 6 PEM A failed or rmvd 7 hr, 37 min
SFM 7 PEM A failed or rmvd 7 hr, 36 min
line card 1 PEM A failed or rmvd 7 hr, 36 min
line card 4 PEM A failed or rmvd 7 hr, 36 min
only 8 SFMs in chassis 7 hr, 35 min
-- Major Alarms --
Alarm Type Duration
----------------------------------------------
No major alarms
FTOS#