show alarms
View alarms for the route process module (RPM), switch fabric modules (SFMs), line cards, and fan trays.
C-Series, E-Series, S-Series, Z-Series
Syntax
show alarms [threshold]
Parameters
threshold (OPTIONAL) Enter the keyword threshold to display the
temperature thresholds set for the line cards, RPM, and SFMs.
Command Modes
EXEC
EXEC Privilege
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
E-Series Original command.
Example
FTOS# show alarms
-- Minor Alarms --
Alarm Type Duration
----------------------------------------------
RPM 0 PEM A failed or rmvd 7 hr, 37 min
SFM 0 PEM A failed or rmvd 7 hr, 37 min
SFM 1 PEM A failed or rmvd 7 hr, 37 min
SFM 2 PEM A failed or rmvd 7 hr, 37 min
SFM 3 PEM A failed or rmvd 7 hr, 37 min
SFM 4 PEM A failed or rmvd 7 hr, 37 min
SFM 5 PEM A failed or rmvd 7 hr, 37 min
SFM 6 PEM A failed or rmvd 7 hr, 37 min
SFM 7 PEM A failed or rmvd 7 hr, 36 min
line card 1 PEM A failed or rmvd 7 hr, 36 min
line card 4 PEM A failed or rmvd 7 hr, 36 min
only 8 SFMs in chassis 7 hr, 35 min
-- Major Alarms --
Alarm Type Duration
----------------------------------------------
No major alarms
FTOS#