dei mark
Set the DEI value on egress according to the color currently assigned to the packet.
C-Series, S-Series, Z-Series, S4810
Syntax
dei mark {green | yellow} {0 | 1}
Parameters
0 | 1 Enter the bit value you want to map to a color.
green | red |
yellow
Choose a color:
Green: High priority packets that are the least preferred to
be dropped.
Yellow: Lower priority packets that are treated as best-
effort.
Defaults All the packets on egress are marked with DEI 0.
Command Modes INTERFACE
Command History
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced on the C-Series and S-Series.
Usage
Information
You must first enable DEI for this configuration to take effect.
Related
Commands
dei enable – enables DEI.
member
Assign a stackable VLAN access or trunk port to a VLAN. The VLAN must contain the vlan-stack compatible
command in its configuration.
C-Series, E-Series, S-Series, Z-Series
Syntax
member interface
To remove an interface from a Stackable VLAN, use the no member interface
command.
Parameters
interface
Enter the following keywords and slot/port or number information:
For a 1-Gigabit Ethernet interface, enter the keyword