EasyManua.ls Logo

Dell Force10 Z9000 - Page 89

Dell Force10 Z9000
1483 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
bootflash-image Enter the keyword bootflash-image to upgrade the bootflash
image.
bootselector-
image
Enter the keyword bootselector-image to upgrade the boot
selector image. Use with technical assistance center (TAC)-
supervision only.
system-image Enter the keyword system-image to upgrade the cache boot
image.
all Enter the keyword all to upgrade the bootflash/boot selector image
on all processors in the E-Series. This keyword does not upgrade the
bootflash on the standby RPM.
linecard
linecard-
slot
Enter the keyword linecard followed by the slot number to change
the bootflash image on a specific line card. For the E-Series, the
range is 0 to 13 on the E1200, 0 to 6 on the E600, and 0 to 5 on the E300.
rpm Enter the keyword rpm to upgrade the bootflash/boot selector image
on all processors on the RPM.
booted Enter this keyword booted to upgrade using the image packed with
the currently running FTOS image.
file-url
Enter the following location keywords and information to upgrade
using an FTOS image other than the one currently running. Enter the
transfer method and file location:
flash:
//filename
ftp:
//userid:password@hostip/filepath
slot0:
//filename
tftp:
//hostip/filepath
where hostip is either an IPv4 dotted
decimal address or an IPv6 URI [x:x:x:x::x] format address.
Defaults none
Command Modes EXEC Privilege
Command History
Version 7.7.1.0 Removed alt-bootflash-image, alt-bootselector-
image, alt-system-image options and the rp1, rp2, and cp
options.
E-Series Original command
Usage
Information
RFC 3986 specifies that IPv6 host addresses in a uniform resource identifier (URI) should be
enclosed in square brackets, [X:X:X:X::X]. For maximum flexibility, this command accepts IPv6
host addresses with or without the square brackets.
A system message appears stating the Bootflash upgrade status. Reload the system to boot
from the upgraded boot images.
After the URL is specified, you can use the same downloaded image for upgrading an individual
RPM, line cards, SFM FPGA, and system-image for cache-boot without specifying the file-url
again using the command upgrade {bootflash-image | bootselector-image |
system-image
} {all | linecard linecard-slot | rpm}. After 20 minutes, the
89

Table of Contents

Other manuals for Dell Force10 Z9000

Related product manuals