Enter the following location keywords and information to upgrade the 
FPGA using an FTOS image other than the one currently running:
• To specify an FTOS image on the internal flash, enter 
flash:// file-path/filename.
• To specify an FTOS image on an FTP server, enter ftp:// 
user:password@hostip/filepath
.
• To specify an FTOS image on the external flash on the 
primary RPM, enter slot0://file-path/filename.
• To copy a file on a TFTP server, enter tftp://hostip/
filepath/ filename where hostip is either an IPv4 
dotted decimal address or an IPv6 URI [x:x:x:x::x] format 
address..
Defaults none
Command Modes EXEC Privilege
Command History
Version 7.7.1.0 Renamed the keywords primary-fpga-flash to fpga-image. 
Added support for upgrading using a remote FTOS image.
Version 7.6.1.0 Added support for the all keyword.
Version 7.5.1.0 Introduced on the C-Series.
Example
FTOS#conf
FTOS(conf)# upgrade primary-fpga-flash rpm
Proceed to upgrade primary fpga flash for rpm 0 [confirm yes/
no]: yes
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
FTOS#
Usage 
Information
Reset the card using the power-cycle option after restoring the FPGA command.
Related 
Commands
• reset – resets a line card or RPM.
• restore fpga-image – this command copies the backup FPGA image to the primary 
FPGA image.