EasyManua.ls Logo

Enterasys Matrix DFE-Gold Series

Enterasys Matrix DFE-Gold Series
944 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring Power over Ethernet (PoE) set inlinepower mode
2-62 Startup and General Configuration
Parameters
None.
Defaults
None.
Mode
Switchcommand,ReadOnly.
Example
ThisexampleshowshowtodisplaydevicePoEproperties.In thiscase,onlythemodulesinslots2
and3arePoEmodules,sotheirpowerconfigurationsdisplay:
Matrix(rw)->show inlinepower
Total Power Detected : 1200 Watts
Total Power Available : 1200 Watts (100% of Total Power Detected)
Total Power Assigned : 0 Watts
Power Allocation Mode : auto
Power Trap Status : disabled
Power Redundancy Status : not redundant
Power Supply 1 Status : installed and operating
Power Supply 2 Status : not installed
Power Supply 3 Status : not installed
Power Supply 4 Status : not installed
Slot Oper Power Power Power Class Power Usage Usage PSE Mgmt
Status Limit Assigned Available Budget Usage Trhld Trap Mode
(W) (W) (W) (W) (W) (%) (%) Status
---- ------ ----- -------- --------- ------ ----- ----- ----- -------- --------
1 on 806 0 598 12 2 75 disabled class
2 on 806 0 599 5 1 75 disabled real-time
3 0
4 0
5 0
6 0
7 0
set inlinepower mode
Usethiscommandtosetthechassispowerallocationmode.
Syntax
set inlinepower mode {auto | manual}

Table of Contents