Configuring Power over Ethernet (PoE) set inlinepower mode
2-62 Startup and General Configuration
Parameters
None.
Defaults
None.
Mode
Switchcommand,ReadOnly.
Example
ThisexampleshowshowtodisplaydevicePoEproperties.In thiscase,onlythemodulesinslots2
and3arePoEmodules,sotheirpowerconfigurationsdisplay:
Matrix(rw)->show inlinepower
Total Power Detected : 1200 Watts
Total Power Available : 1200 Watts (100% of Total Power Detected)
Total Power Assigned : 0 Watts
Power Allocation Mode : auto
Power Trap Status : disabled
Power Redundancy Status : not redundant
Power Supply 1 Status : installed and operating
Power Supply 2 Status : not installed
Power Supply 3 Status : not installed
Power Supply 4 Status : not installed
Slot Oper Power Power Power Class Power Usage Usage PSE Mgmt
Status Limit Assigned Available Budget Usage Trhld Trap Mode
(W) (W) (W) (W) (W) (%) (%) Status
---- ------ ----- -------- --------- ------ ----- ----- ----- -------- --------
1 on 806 0 598 12 2 75 disabled class
2 on 806 0 599 5 1 75 disabled real-time
3 0
4 0
5 0
6 0
7 0
set inlinepower mode
Usethiscommandtosetthechassispowerallocationmode.
Syntax
set inlinepower mode {auto | manual}

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Enterasys Matrix DFE-Gold Series Specifications

General IconGeneral
BrandEnterasys
ModelMatrix DFE-Gold Series
CategorySwitch
LanguageEnglish

Related product manuals