clear snmp targetaddr Configuring SNMP Target Addresses
Enterasys Matrix DFE-Gold Series Configuration Guide 5-31
Defaults
•Ifnotspecified,udpportwillbesetto162.
•Ifnotspecified,maskwillbesetto255.255.255.25 5
•Ifnotspecified,timeoutwillbesetto1500.
•Ifnotspecified,numberofretrieswillbesetto3.
•Iftaglistisnotspecified,nonewillbeset.
•Ifnotspecified,storagetype
willbenonvolatile.
Mode
Switchcommand,ReadWrite.
Usage
ThetargetaddressisauniqueidentifierandaspecificIPaddressthatwillreceiveSNMP
notificationmessagesanddeterminewhichcommunitystringswillbeaccepted.Thisaddress
configurationcanbelinkedtooptionalSNMPtransmitparameters(suchastimeout,retrycount,
andUDPport).
Example
Thisexampleshowshowtoconfigureatrapnotificationcalled“TrapSink.”Thistrapnotification
willbesenttotheworkstation192.168.190.80(whichistargetaddress“tr”).Itwillusesecurity
andauthorizationcriteriacontainedinatargetparametersentrycalled“v2cExampleParams”.For
moreinformationoncreatingabasicSNMPtrap,refer
toCreatingaBasicSNMPTrap
Configurationonpage 53:
Matrix(rw)->set snmp targetaddr tr 192.168.190.80 param v2cExampleParams taglist
TrapSink
clear snmp targetaddr
UsethiscommandtodeleteanSNMPtargetaddressentry.
Syntax
clear snmp targetaddr targetAddr
Parameters
Defaults
None.
taglisttaglist (Optional)SpecifiesalistofSNMPnotifytagvalues.Thistagsalocation
tothetargetaddressasaplacetosendnotifications.Listmustbe
enclosedinquotesandtagvaluesmustbeseparatedbyaspace(i.e.:
“tag1tag2”)
volatile|nonvolatile (Optional)Specifiestemporary
(default),orpermanentstoragefor
SNMPentries.
targetAddr Specifiesthetargetaddressentrytodelete.