Page #233 background image
clear linkflap down Configuring Link Traps and Link Flap Detection
Enterasys Matrix DFE-Gold Series Configuration Guide 4-47
clear linkflap down
Usethiscommandtotogglelinkflapdisabledportstooperational.
Syntax
clear linkflap down [port-string]
Parameters
Defaults
Ifportstringisnotspecified,allportsdisabledbyalinkflapviolationwillbemadeoperational.
Mode
Switchcommand,ReadWrite.
Examples
Thisexampleshowshowtomakedisabledportfe.1.4operational:
Matrix(rw)->clear linkflap down fe.1.4
clear linkflap
Usethiscommandtoclearalllinkflapoptionsand/orstatisticsononeormoreports.
Syntax
clear linkflap {all | stats [port-string] | parameter port-string {threshold |
interval | downtime | all}
Parameters
Defaults
Ifportstringisnotspecified,settingsand/orstatisticswillbeclearedonallports.
Mode
Switchcommand,ReadWrite.
portstring Specifiestheport(s)tomakeoperational.Foradetaileddescriptionof
possibleportstringvalues,refertoPortStringSyntaxUsedintheCLI
onpage 42.
all|stats Clearsalloptionsandstatistics,orclearsonlystatistics.
parameter Clearslinkflapparameters.
threshold|interval|
downtime|all
Clearslinkflapthreshold,interval,downtimeorallparameters.
portstring (Optionalunlessparameterisspecified)Specifiestheport(s)onwhich
toclearsettings.Foradetaileddes criptionofpossible
portstringvalues,
refertoPortStringSyntaxUsedintheCLIonpage 42.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Enterasys Matrix DFE-Gold Series Specifications

General IconGeneral
BrandEnterasys
ModelMatrix DFE-Gold Series
CategorySwitch
LanguageEnglish

Related product manuals