EasyManua.ls Logo

Enterasys Matrix DFE-Gold Series

Enterasys Matrix DFE-Gold Series
944 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring Power over Ethernet (PoE) set inlinepower management
2-68 Startup and General Configuration
Example
ThisexampleshowshowtoresetthePoEthresholdto75onmodule1:
Matrix(rw)->clear inlinepower threshold 1
set inlinepower management
UsethiscommandtosetthePoEmanagementmodeonaspecifiedmodule.
Syntax
set inlinepower management {realtime | class} module-number
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Example
ThisexampleshowshowtosetthePoEmanagementmodeto“class”onmodule1:
Matrix(rw)->set inlinepower management class 1
clear inlinepower management
UsethiscommandtoresetthePoEmanagementmodeonaspecifiedmodulebacktothedefault
settingof“realtime”.
Syntax
clear inlinepower management module-number
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
realtime Managespowerbasedontheactualpowerconsumptionoftheports.
class ManagespowerbasedontheIEEE802.3afdefinitionoftheclassupper
limit,exceptclasses0and4,forwhichtheactualpowerconsumptionis
used.
modulenumber SpecifiesthemoduleonwhichtosetthePoE
managementmode.
modulenumber SpecifiesthemoduleonwhichtoresetthePoEmanagementmode.

Table of Contents