clear physical alias Setting Basic Device Properties
Enterasys Matrix DFE-Gold Series Configuration Guide 2-55
Mode
Switchcommand,ReadWrite.
Example
Thisexampleshowshowtosetthealiasforthechassisto“chassisone”:
Matrix(rw)->set physical alias chassis chassisone
clear physical alias
Usethiscommandtoresetthealiasforaphysicalobjecttoazerolengthstring.
Syntax
clear physical alias {[chassis] [slot slot] [backplane backplane] [module module]
[powersupply powersupply] [powersupply-slot powersupply-slot] [fan] [fan-slot]
[port-string port-string]}
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Example
Thisexampleshowshowtosetclearthealiassetforthechassis:
Matrix(rw)->clear physical alias chassis
show physical assetid
UsethiscommandtodisplaytheassetIDforamodule.
Syntax
show physical assetid module module
chassis Clearsthechassisalias.
slotslot Clearsandaliasforaspecificslot.
backplanebackplane Clearsandaliasforaspecificbackplane.Validvaluesare1forFTM1
and2forFTM2.
modulemodule Clearsanaliasforaspecificmodule.
powersupply
powersupply
Clearsanaliasforaspecificpowersupply.
Validvaluesare1or2.
fan Clearsthefantrayalias
portstringportstring Clearsanaliasforaspecificport.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Enterasys Matrix DFE-Gold Series Specifications

General IconGeneral
BrandEnterasys
ModelMatrix DFE-Gold Series
CategorySwitch
LanguageEnglish

Related product manuals