Configuring Port Web Authentication (PWA) show pwa
25-14 Authentication Configuration
Table 25-1 show pwa Output Details
Output... What it displays...
PWA Status Whether or not port web authentication is enabled or disabled. Default
state of disabled can be changed using the set pwa command as
described in “set pwa” on page 25-15.
PWA IP Address IP address of the end station from which PWA will prevent network
access until the user is authenticated. Set using the set pwa
ipaddress command as described in “set pwa ipaddress” on
page 25-19.
PWA Protocol Whether PWA protocol is CHAP or PAP. Default setting of PAP can be
changed using the set pwa protocol command as described in “set pwa
protocol” on page 25-19.
PWA Enhanced Mode Whether PWA enhanced mode is enabled or disabled. Default state of
disabled can be changed using the set pwa enhancedmode
command as described in “set pwa enhancedmode” on page 25-20.
PWA Logo Whether the Enterasys Networks logo will be displayed or hidden at
user login. Default state of enabled (displayed) can be changed using
the set pwa displaylogo command as described in “set pwa
displaylogo” on page 25-18.
PWA Guest Networking Status Whether PWA guest user status is disabled or enabled with RADIUS
or no authentication. Default state of disabled can be changed using
the set pwa gueststatus command as described in “set pwa
gueststatus” on page 25-22.
PWA Guest Name Guest user name for PWA enhanced mode networking. Default value
of “guest” can be changed using the set pwa guestname command as
described in “set pwa guestname” on page 25-21.
PWA Guest Password Guest user’s password. Default value of an empty string can be
changed using the set pwa guestpassword command as described in
set pwa guestpassword” on page 25-22.
PWA Redirect Time Time in seconds after login success before the user is redirected to the
PWA home page. Default of 5 can be reset using the set pwa
redirecttime command as described in “set pwa redirecttime” on
page 25-18.
Port PWA port designation.
Mode PWA port control mode.
Auth Status Whether or not the port state is disconnected, authenticating
authenticated, or held (authentication has failed).
Quiet Period Amount of time a port will be in the held state after a user
unsuccessfully attempts to log on to the network. Default value of 60
can be changed using the set pwa quietperiod command as
described in “set pwa quietperiod” on page 25-23.
MaxReq Maximum number of log on attempts allowed before transitioning the
port to a held state. Default value of 2 can be changed using the set
pwa maxrequests command as described in “set pwa maxrequests
on page 25-24.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Enterasys Matrix DFE-Gold Series Specifications

General IconGeneral
BrandEnterasys
ModelMatrix DFE-Gold Series
CategorySwitch
LanguageEnglish

Related product manuals